A restaurant floor drain keeps backing up because grease and food solids have narrowed the branch line between that drain and the grease trap.
Floor drains and floor sinks are the lowest openings in a commercial kitchen, so they show a blockage first. Count the drains that are acting up. One drain points to its own branch line. Several kitchen drains point to a shared line or the grease trap. Kitchen and restroom drains together point to the main sewer line.
James Armstrong Plumbing is a Mesquite plumbing company led by Texas Master Plumber James Armstrong. We clear grease lines, kitchen drains and floor drains, and we repair the plumbing around grease traps and interceptors. Our page on restaurant plumbing in Dallas covers our restaurant drain cleaning and kitchen work.
Key takeaways
- One floor drain backing up usually means grease and solids in its own branch line.
- Several kitchen drains backing up means a shared line, the grease trap, or the line past it.
- Kitchen and restroom drains backing up together means the main sewer line.
- A sewer smell with no backup usually means a dry trap in a drain nobody uses.
- The grease trap protects only the pipe downstream of it.
How do you tell where a restaurant drain blockage is?
When a floor drain backs up, count the drains that are acting up; the number tells you how far down the line the blockage sits.
- One floor drain or floor sink: that drain’s own trap or branch line.
- Several kitchen drains: the line they share, the grease trap or interceptor, or the line past it.
- Kitchen and restroom drains together: the building’s main sewer line.
Why does grease clog the line before the grease trap?
Cause 1 is grease in the branch line, the usual reason a restaurant floor drain keeps backing up. Grease leaves the sink or dish machine warm, cools in the pipe and coats the wall. Food solids stick to it, and each service adds a layer until the floor drain backs up.
A grease trap or grease interceptor is a tank that holds kitchen waste water long enough for grease to float and solids to settle. It protects the sewer downstream; the lines between the kitchen fixtures and the trap get no protection. Our guide to the grease trap vs grease interceptor explains how each one works.
Some floor drains sit on the grease side. Section 1003.3.1 of the 2021 International Plumbing Code (IPC), the model code published by the International Code Council, lists “floor drains or sinks into which kettles are drained” among fixtures that must drain to a grease interceptor or automatic grease removal device.
A U.S. Environmental Protection Agency (EPA) fact sheet on controlling fats, oils and grease from food service establishments cites a 2004 EPA Report to Congress: grease is the most common cause of reported sewer blockages, at 47 percent, because it “solidifies, reduces conveyance capacity, and blocks flow.”
What if the blockage is past the grease trap?
Cause 2 is a blockage on the far side of the trap. If several kitchen drains back up and the trap or interceptor has room, the blockage may sit between the unit and the building’s sewer, where grease from an overloaded unit builds up too.
If the trap or interceptor itself is full, it needs service from whoever services it. A full unit holds water back like a clogged pipe. If it has room and the kitchen still backs up, the problem is in the pipe.
The City of Dallas requires a grease trap for any commercial or institutional food service operation, per the Dallas Water Utilities Pretreatment Program FAQ, which uses that term for interceptors too. So a Dallas restaurant has pipe on both sides of the unit, and either side can clog.
Why does a floor drain smell like sewage when it is not backed up?
Cause 3 is a dry trap letting sewer gas in. Every floor drain has a trap, a bend that holds water as a seal against sewer gas. Section 1002.4 of the 2021 IPC sets that seal at 2 to 4 inches of water.
A drain nobody uses loses that water to evaporation until sewer gas comes up into the room. Section 1002.4.1 requires trap seals subject to evaporation to be protected, for example by a trap seal primer valve or a barrier-type device. Your city’s adopted code decides what applies to your building.
A rotten-egg smell comes from hydrogen sulfide. The Occupational Safety and Health Administration (OSHA) notes that some people notice it at low levels, and that high concentrations cause loss of smell. A smell that fades is not proof the problem is gone.
Pour a bucket of water down an occasional dry drain to refill the seal. A drain that keeps drying out may need a trap primer. If the smell persists with the trap full, a smoke test can find cracked pipe or an open vent.
What solids clog a floor drain or floor sink?
Cause 4 is solids that should not be in the drain. Without a strainer, a floor drain catches food scraps, mop strings, plastic wrap, gloves, labels and broken glass. They catch on the trap and the first fitting, and grease builds on them.
A floor sink is the indirect drain receptor under ice machines, prep sinks and other food service equipment. Mineral scale and slime from equipment drain lines settle in it, and a missing grate lets everything else in.
Keep a strainer in every floor drain and floor sink, and empty it into the trash.
When is it the main sewer line?
Cause 5 is a main sewer line problem, and the sign is kitchen and restroom drains backing up together. Grease that made it past the trap, roots at an old joint, a sag under the slab, or cracked older cast iron pipe can all cause it.
A main line problem rarely clears for good with one cleaning. If the building backs up more than once, a camera inspection shows what is inside the pipe and where. Our page on sewer line plumbing in Dallas covers the repairs.
What can kitchen staff check before calling a plumber?
Six quick checks tell the plumber where to start.
- Stop sending water to the floor. Hold the dish machine and the three-compartment sink.
- Count the drains. One drain, several kitchen drains, or kitchen plus restrooms.
- Pull the strainer or grate and remove debris you can reach with gloves.
- Think about the grease trap or interceptor. If it may be full, call whoever services it. Leave in-ground lids closed.
- Smell the drain. A sewer odor with no backup points to a dry trap. Pour a bucket of water down it.
- Note when it happens, such as the dish rush or closing cleanup.
What should staff not do with a backed-up floor drain?
Three common fixes make a grease line worse.
- Do not pour chemical drain openers into the drain. They rarely clear a grease line, and they leave caustic water in the pipe for whoever opens it next.
- Do not pour boiling water or extra detergent down it. They can carry the grease farther down the line, where it sets again.
- Do not open a cleanout on a backed-up line. The water behind it can come out with force.
How does a plumber clear a commercial kitchen floor drain?
Commercial kitchen drain cleaning starts at the drain that backed up and works out how far down the blockage sits. A single floor drain gets cabled through its trap, which punches a hole through the blockage.
For a grease line that clogs again and again, commercial hydro jetting scours grease off the pipe wall. Our comparison of hydro jetting vs snaking for commercial lines explains when each fits.
A camera inspection shows whether a sag, a break or scaled cast iron is catching the grease, and whether the pipe is sound enough to jet. We also install and replace floor sinks that are cracked or undersized.
How do you keep a restaurant floor drain from backing up again?
Keep grease and solids out of the floor drain, and keep water in the traps nobody uses.
- Scrape plates and pans into the trash before they reach the sink.
- Pour water down rarely used drains so their seals stay full.
- Call a plumber when the same floor drain backs up twice. Something in the pipe is catching grease, and a camera inspection finds it.
Frequently asked questions
Why does the kitchen floor drain keep backing up?
Grease and food solids build up in the branch line between the floor drain and the grease trap, which protects only the pipe downstream of it.
Why do several kitchen drains back up at the same time?
The blockage is in a line they share, usually the run to the grease trap or interceptor or the line past it. If the restroom drains back up too, the blockage is in the main sewer line.
Why does a floor drain smell like sewage?
The trap has usually dried out and lets sewer gas into the room. Pouring a bucket of water down the drain refills the seal.
Can a full grease trap make the floor drain back up?
Yes. A full trap or interceptor holds water back like a clogged pipe. If the unit has room and the kitchen still backs up, the blockage is in the pipe.
Should staff use chemical drain cleaner on a restaurant floor drain?
We advise against it. Chemical drain openers rarely clear a grease line, and they leave caustic water in the pipe for whoever opens it next.
Is hydro jetting better than cabling for a restaurant drain?
For grease, usually. Cabling punches a hole through the blockage, while hydro jetting scours grease off the pipe wall. A camera inspection first shows whether the pipe is sound enough to jet.
Restaurant floor drain backing up again?
Call James Armstrong Plumbing at 214-918-6109. A licensed plumber will find the blockage, clear it and explain what we found. See our commercial plumbing services for the rest of what we do for businesses.
About James Armstrong Plumbing
James Armstrong Plumbing was founded in 1995 and has more than 30 years of experience. James Armstrong is a Texas Master Plumber, License M-39428. We are licensed and insured, and BBB A+ rated since 2018. Our shop is at 844 Dalworth Dr, Suite 10, Mesquite, TX 75149. Call 214-918-6109.
This article is general information, not professional advice.
Count the drains that are acting up. That one check tells you where the problem sits and who handles it.
| What staff see | Where the problem is | What staff can check | Who handles it |
|---|---|---|---|
| One floor drain or floor sink backs up | Grease and solids in that drain’s trap or branch line | Pull the strainer or grate and remove debris you can reach with gloves | A plumber, to cable the line through the trap |
| Several kitchen drains back up, and the trap has room | The shared line to the grease trap or interceptor, or the line past it | Hold the dish machine and the three-compartment sink | A plumber, to clear the grease line and camera it if it keeps coming back |
| Several kitchen drains back up, and the trap is full | The grease trap or interceptor itself | Call whoever services the unit; leave in-ground lids closed | The unit needs service from whoever services it |
| Sewer smell, no backup | A dry trap in a drain nobody uses | Pour a bucket of water down the drain to refill the seal | A plumber if it keeps drying out (trap primer) or the smell stays (smoke test) |
| Drain clogs with debris | Solids in the trap and first fitting, or scale in a floor sink | Keep a strainer in every floor drain and floor sink, and empty it into the trash | A plumber, to clear the trap or replace a cracked floor sink |
| Kitchen and restroom drains back up together | The building’s main sewer line | Hold the dish machine and sinks; do not open a backed-up cleanout | A plumber, to clear the main line and camera it |
We clear grease lines, kitchen drains and floor drains, and repair the plumbing around grease traps and interceptors. Call 214-918-6109.